Bearing Mounted Electromagnetic Clutch Type EBMC (Normally Off)
Bearing Mounted Electromagnetic Clutch Type EBMC (Normally Off)
EXCEL bearing and flange mounted clutches are normally off type and require DC voltage for operation. When stator (1) is supplied with D.C. voltage the armature plate (5) is attracted towards the friction material (4) of the rotor (3) over the air gap and torque gets transmitted free of backlash. When the supply is switched off the prestressed springs (6) pulls the armature (5) back into its original position free of residual torque even when mounted vertically.
Source:- http://www.excelclutchbrake.com/bearing-mounted-electromagnetic-clutch-type-ebmc-normally-off-.html
Bearing Mounted Electromagnetic Clutch Type EBMC (Normally Off)
Salient Features
- Simple construction
- Stationary field (No slip ring)
- Slotted armature for torque stability
- Single plate dry type
- High operating reliability & frequency
- Maintenance free simple construction
- Unique pre-stressed springs
- Coil with class 'F' Insulation
- No restrictions on mounting positions
Working of EBMC
EXCEL bearing and flange mounted clutches are normally off type and require DC voltage for operation. When stator (1) is supplied with D.C. voltage the armature plate (5) is attracted towards the friction material (4) of the rotor (3) over the air gap and torque gets transmitted free of backlash. When the supply is switched off the prestressed springs (6) pulls the armature (5) back into its original position free of residual torque even when mounted vertically.
Description
1. Stator
2. Coil
3. Rotor
4. Friction Liner
5. Armature Plate
6. Spring
7. Flange
8. Bearing
2. Coil
3. Rotor
4. Friction Liner
5. Armature Plate
6. Spring
7. Flange
8. Bearing